Marmonix MEF-8700 Partial-Fill Mag Flow Meter
Electromagnetic flow meter for partly full gravity pipes, DN200 to DN3000. It measures from 10% to 100% fill by combining mag-meter velocity with an ultrasonic level sensor (±1 mm), with 2.5% accuracy from 0.05 to 10 m/s. It has a remote LCD converter, Modbus/RS485 output and a solar power option for irrigation and wastewater sites.
The Marmonix MEF-8700 partially filled pipe electromagnetic flow meter measures volume flow in large gravity lines, DN200 to DN3000, that do not always run full. A standard mag meter needs a full pipe; the MEF-8700 adds a mini ultrasonic level sensor to the electromagnetic flow tube, so it keeps measuring from 10% fill up to 100%. Municipal utilities, irrigation authorities, wastewater treatment plants and EPC contractors across the UAE and GCC use it on irrigation mains, treated-effluent and sewage lines where a weir or flume would be costly or impractical. It sits in the Marmonix flow meters range.
Why choose the MEF-8700
- Measures partly full pipes: from 10% to 100% fill, so flow is counted during low-demand hours as well as at peak.
- Level and velocity in one meter: the ultrasonic level sensor resolves the liquid surface to about ±1 mm and the converter calculates volume flow automatically.
- Large diameters: DN200 to DN3000 flanged spools, at 0.6, 1.0 or 1.6 MPa.
- Works off-grid: 220 VAC, 24 VDC or 12 V supply, with a solar power option for remote canals, farms and outfalls.
- SCADA-ready: Modbus RTU over RS232/RS485 as standard, with 4–20 mA, pulse and HART available by order code.
- Durable build: neoprene or polyurethane liner (food-grade certified for drinking water), a range of electrode metals, IP65 converter and IP68 sensor option. The manufacturer expects at least 5 to 10 years of service.
Applications
- Irrigation networks and agricultural water distribution, including farms and landscaping fed by treated water.
- Wastewater and sewage gravity mains, pumping station outfalls and treatment plant inlets.
- Drinking water and groundwater transfer lines in large diameters.
- Water treatment plants and industrial effluent lines.
- Paper pulp and other non-corrosive liquids from −20 to 60 °C.
How the MEF-8700 works
Like any electromagnetic flow meter, the MEF-8700 has no moving parts: the liquid moving through a magnetic field generates a small voltage at the electrodes that is proportional to its velocity. In a part-full pipe, velocity alone is not enough, because the wetted area changes with level. The built-in ultrasonic sensor measures the liquid height, the converter works out the wetted flow area from it and multiplies area by velocity to give volume flow. The remote converter shows the reading on its LCD and sends it to your control system.
MEF-8700 technical specifications
| Parameter | MEF-8700 |
|---|---|
| Pipe size | DN200 to DN3000 |
| Measurable fill level | 10% to 100% of the pipe |
| Measuring principle | Electromagnetic velocity measurement plus a mini ultrasonic level sensor (level accuracy up to ±1 mm, very small blind area) |
| Accuracy | 2.5% |
| Flow velocity range | 0.05 to 10 m/s |
| Process connection | Flange |
| Nominal pressure | 0.6 MPa, 1.0 MPa or 1.6 MPa (by order code) |
| Liner | Neoprene or polyurethane (food-grade certified liner for drinking water) |
| Electrodes | 316L stainless steel, Hastelloy B, Hastelloy C, titanium, tantalum, or stainless steel coated with tungsten carbide |
| Construction | Remote type (converter separate from sensor); submersible remote version available |
| Medium temperature | −20 to 60 °C |
| Power supply | 220 VAC 50 Hz, 24 VDC or 12 V; solar power option for sites without mains |
| Outputs | Modbus RTU and TTL level; RS232/RS485; order options for 4–20 mA with pulse, RS232 or RS485, or HART |
| Display | Remote LCD converter showing the flow reading |
| Protection | Converter IP65; flow sensor IP65 standard, IP68 optional |
| Typical service life | At least 5 to 10 years (manufacturer statement) |
Dimensions at 0.6 MPa (DN200 to DN1000)
From the manufacturer datasheet; all dimensions in mm. Sizes above DN1000 and higher pressure classes are supplied to order.
| Size | Length L | Height H | Flange OD ØA | Bolt circle ØK | Bolt holes N × Øh |
|---|---|---|---|---|---|
| DN200 | 400 | 494 | 320 | 280 | 8 × Ø18 |
| DN250 | 450 | 561 | 375 | 335 | 12 × Ø18 |
| DN300 | 500 | 623 | 440 | 395 | 12 × Ø22 |
| DN350 | 550 | 671 | 490 | 445 | 12 × Ø22 |
| DN400 | 600 | 708 | 540 | 495 | 16 × Ø22 |
| DN450 | 600 | 778 | 595 | 550 | 16 × Ø22 |
| DN500 | 600 | 828 | 645 | 600 | 20 × Ø22 |
| DN600 | 600 | 934 | 755 | 705 | 20 × Ø22 |
| DN700 | 700 | 1041 | 860 | 810 | 24 × Ø26 |
| DN800 | 800 | 1149 | 975 | 920 | 24 × Ø30 |
| DN900 | 900 | 1249 | 1075 | 1020 | 24 × Ø30 |
| DN1000 | 1000 | 1359 | 1175 | 1120 | 28 × Ø30 |
Installation guidelines
- Allow 10D of straight pipe upstream and 5D downstream (D = pipe diameter), away from elbows, valves and pumps.
- Install at the lowest point of the line and, on vertical sections, with flow going upward.
- Do not install at the highest point of the pipe or on a vertical pipe with downward flow, where air collects.
- In open drain lines, place the meter at the lowest point.
- Fit the meter on the outlet side of a pump, not the inlet.
- Where the line drops more than 5 m after the meter, add an air release (exhaust) valve downstream.
Routine maintenance is mostly visual: keep the converter clean and dry, check the wiring, and clean the electrodes and tube if the liquid leaves deposits. If readings look wrong, check the power supply, signal cables, air bubbles and leaks before opening the meter.
MEF-8700 vs other Marmonix electromagnetic flow meters
| MEF-8700 partial fill | MEF-8200 flanged | MEF-8300 insertion | |
|---|---|---|---|
| Best for | Gravity lines that run partly full | Full pipes, any conductive liquid | Full large pipes where a spool is impractical |
| Pipe size | DN200–DN3000 | DN3–DN3000 | DN100–DN3000 |
| Works when the pipe is partly full | Yes, from 10% fill | No | No |
| Accuracy | 2.5% | ±0.5% standard (±0.3%/±0.2% optional) | 1.5% |
| Velocity | 0.05–10 m/s | Up to 15 m/s | Up to 15 m/s |
| Installation | Flanged spool, remote converter | Flanged spool, integral or remote | Insertion probe, hot-tap possible |
| Solar power option | Yes | — | — |
Choose the MEF-8200 flanged mag meter when the pipe is always full and you need higher accuracy, or the MEF-8300 insertion mag meter for large full pipes where cutting in a spool is not practical. For open channels and tanks where you only need level, see our level transmitters and ultrasonic level meters, and the guide to radar and ultrasonic level transmitters.
Ordering the MEF-8700 in the UAE and GCC
Each MEF-8700 is configured to order. Send us the pipe size, pressure class, liquid and temperature, electrode material, power supply and required output, and Marmonix will confirm the model code, a quotation and delivery time for the UAE, Saudi Arabia, Oman, Qatar, Kuwait or Bahrain. The full datasheet is in the Downloads tab.
MEF-8700 partially filled pipe flow meter FAQ
What is a partially filled pipe electromagnetic flow meter?
It is a mag meter designed for pipes that do not always run full, such as gravity sewers and irrigation mains. The MEF-8700 measures flow velocity electromagnetically and the liquid level with a built-in ultrasonic sensor, then combines the two to calculate the actual volume flow.
From what fill level can the MEF-8700 measure?
From 10% of the pipe height up to a completely full pipe, in sizes from DN200 to DN3000.
How accurate is the MEF-8700?
The datasheet gives 2.5% accuracy over a flow velocity range of 0.05 to 10 m/s. The ultrasonic level sensor resolves the liquid level to about ±1 mm.
Can the MEF-8700 run on solar power?
Yes. Besides 220 VAC, 24 VDC and 12 V supplies, a solar power option is available for remote irrigation and drainage sites with no mains supply.
What liquids is it suitable for?
Water, wastewater, irrigation water, groundwater and drinking water, and paper pulp, at medium temperatures from −20 to 60 °C. The neoprene or polyurethane liner suits most non-corrosive liquids, and the electrode metal is chosen to suit the liquid.
What straight pipe run does the MEF-8700 need?
Allow at least 10 pipe diameters of straight pipe upstream and 5 diameters downstream, and keep elbows, valves and pumps away from the meter. Install it at a low point of the line, not at the highest point.
What information do you need to quote an MEF-8700?
Pipe size (DN), pressure class, liquid and temperature, preferred electrode material, power supply (mains, 24 VDC, 12 V or solar) and the output you need (Modbus/RS485, 4–20 mA, pulse or HART).
| Brand |
Marmonix |
|---|---|
| IP rating |
IP65 ,IP68 |
| Display |
LCD |
| Connectivity & outputs |
4-20 mA ,HART ,Modbus RTU ,Pulse output ,RS232 ,RS485 |
| Power source |
220 V AC mains ,24 V DC ,Solar power option |
| Features |
Partial-fill measurement |
| Applications |
Water & wastewater |
| Measuring principle |
Electromagnetic |
| Measured medium |
Liquid |
| Mounting / format |
Flanged |
| Pipe size range |
DN200-DN3000 |
| Accuracy |
±2.5% |