Marmonix MVD-335 PRO Wireless High-Voltage Phase Detector, 10 V–500 kV

SKU: MVD-335-PRO Category:

Wireless high-voltage phase detector for 10 V to 500 kV: in-phase/out-of-phase, phase angle (0–360°, ±12°), phase sequence and frequency, with detectors up to 200 m from the host. Contact and non-contact modes, vector diagram, voice prompts and 200 stored results.

WhatsApp
Email
Telegram
Description

The Marmonix MVD-335 PRO wireless high-voltage phase detector is for substation, utility and switchgear teams who need to confirm phasing before they close a tie, parallel two supplies or connect a new cable. Two wireless detectors on insulating rods send the signal to one handheld host up to 200 m away. The host shows whether the two conductors are in phase, the phase angle, the phase sequence and the frequency, on one screen with a vector diagram and voice prompts.

One kit phases from 10 V to 500 kV, so you do not need a separate phasing set for each voltage level. It is part of our phase detectors range. For other tests on the same jobs, see our complete guide to electrical test and measurement instruments.

Why choose the MVD-335 PRO

  • 10 V to 500 kV in one kit: LV panels, 11 kV and 33 kV ring main units and switchgear, and HV substation busbars and lines
  • 200 m wireless phasing: phase two feeders, two cable ends or two substations’ busbars without a cable between the probes
  • Contact and non-contact modes: contact on bare conductors below 35 kV or covered conductors up to 500 kV; non-contact on HV bare conductors
  • Numbers, not just a lamp: phase angle 0–360° (±12°), frequency 45–65 Hz (±2 Hz) and phase sequence, with a live vector diagram
  • Clear go/no-go: in phase from −25° to +25°; out of phase at 95°–145° or 215°–265°, with a spoken result
  • Live-line check: shows the voltage level from 0.1 to 35 kV
  • Records for reports: stores 200 results and uploads them for commissioning and switching records

Where the MVD-335 PRO is used

  • Substation commissioning: phasing new transformers, incomers and bus sections before energising
  • Ring closing and paralleling: checking that two 11 kV or 33 kV feeders are in phase before you close a normally-open point
  • Cable jointing and repair: confirming core identity and phase at both ends of a new or repaired HV cable
  • Generators and standby supplies: phase checks before synchronising or transferring load
  • Industrial plants and data centres: phasing dual utility supplies, switchgear line-ups and LV boards

MVD-335 PRO specifications

Values are taken from the official Marmonix MVD-335 PRO datasheet (Downloads tab).

Parameter MVD-335 PRO
Functions High-voltage phasing (in phase / out of phase), phase angle, phase sequence, frequency and live-line (electricity) inspection
Phasing voltage AC 10 V to 500 kV
Phase angle 0.0°–360.0°; accuracy ≤ ±12°; resolution 0.1°
Frequency 45.0–65.0 Hz; accuracy ≤ ±2 Hz; resolution 0.1 Hz
Phase result In phase: −25° to +25° · Out of phase: 95°–145° and 215°–265°
Wireless phasing distance Up to 200 m between the two detectors and the host
Radio frequency 433 MHz and 315 MHz
Voltage display range 0.1–35 kV
Contact phasing Bare conductors below 35 kV, or insulated (covered) conductors up to 500 kV
Non-contact phasing For high-voltage bare conductors (stated in the datasheet for bare wire above 220 kV): the probe is moved slowly towards the conductor until it picks up the electric field
Display and prompts Colour display with vector (phasor) diagram, phase indication and voice prompts
Data 200 stored records with data upload
Power supply Host: 9 V DC from 6 × AA alkaline batteries · Detectors: 9 V 6F22 battery each
Model / SKU MVD-335 PRO

How to phase two conductors with the MVD-335 PRO

  1. Check the batteries in the host and in both detectors, and switch on all three units.
  2. Fit each detector to its insulating rod with the correct probe or hook for the voltage and the type of conductor.
  3. Do a self-check on a known source, if your procedure requires it, so you know both radio links work.
  4. Bring detector X to the first conductor and detector Y to the second: touch in contact mode, or approach slowly in non-contact mode.
  5. Read the result on the host: phase angle, vector diagram and the voice prompt for in phase or out of phase. Repeat for each phase pair.
  6. Save the result, and upload the records afterwards for your commissioning or switching report.

Safety: high-voltage phasing is live work. Only trained, authorised staff should use the MVD-335 PRO, with approved insulating rods and PPE, safe clearances and your utility’s or site’s switching procedure.

Related instruments

Compare the MVD-335 for networks up to 220 kV, and the MPQ400 PRO power quality analyzer for voltage, harmonics and phase angle on live LV systems. Before energising new cables and switchgear, test the insulation; our insulation tester buying guide explains which test voltage to use.

MVD-335 PRO vs other phase detectors sold in the UAE and GCC

Figures are from the sellers’ or makers’ published pages at the time of writing; “—” means the value was not stated. The MVD-335 PRO matches the widest phasing range in its class (10 V–500 kV) and adds a long 200 m link, a live-line voltage display and voice prompts.

Model Phasing voltage Wireless distance Phase accuracy / resolution Frequency Notes
Marmonix MVD-335 PRO 10 V–500 kV 200 m ≤ ±12° / 0.1° 45–65 Hz, ±2 Hz 200 records, voice prompts, phasor diagram, live-line check
Marmonix MVD-335 200 V–220 kV 30 m — 45–65 Hz, ±2 Hz 9999 records, 3.5-inch colour screen
SISCO wireless phase detector 10 V–500 kV Up to 260 m — 45–65 Hz 200 groups, USB upload, 3.5-inch screen
GAOTek wireless HV phase sequence tester 10 V–500 kV 200–260 m ≤ ±10° / 1° 45–65 Hz, ±2 Hz 200 groups, rechargeable batteries
ES2080A+ wireless phasing meter 30 V–550 kV About 200 m ≤ ±10° / 0.1° 30–100 Hz, ±1 Hz 500 groups, 2.4 GHz link
Multimic DPP-36 20–36 kV only Under 5 m LED/beeper only 50/60 Hz No phase angle display

Marmonix supplies the MVD-335 PRO directly across the UAE, Saudi Arabia, Oman, Qatar, Kuwait and Bahrain, with the official datasheet and local technical support. Contact us for the kit contents, a quote or a demonstration.

MVD-335 PRO phase detector FAQ

What does the MVD-335 PRO actually measure?

It compares two conductors and tells you whether they are in phase or out of phase, and shows the phase angle between them (0–360°, ±12°), the phase sequence and the frequency (45–65 Hz). It also works as a live-line indicator, showing the voltage level from 0.1 to 35 kV.

What voltage range does it cover?

Phasing works from 10 V up to 500 kV, so one kit covers low-voltage panels, 11 kV and 33 kV distribution switchgear and high-voltage substations. That replaces separate phasing sticks for each voltage level.

When should I use contact mode, and when non-contact mode?

Contact phasing is for bare conductors below 35 kV or insulated conductors up to 500 kV. On high-voltage bare conductors, use non-contact mode: move the probe slowly towards the conductor on the insulating rod until the detector picks up the electric field. Follow the user manual and your site’s live-working rules for each voltage level.

How far apart can the two detectors be?

Up to 200 m. Each detector sends its signal to the host by radio (433/315 MHz), so you can phase two feeders, two ends of a cable or two switchboards without a long cable between the probes.

How do I know the result is in phase?

The host shows the phase angle and the vector diagram and gives a voice prompt. Angles from −25° to +25° count as in phase. Angles of 95°–145° or 215°–265° count as out of phase, which is what you see on two different phases of a three-phase system.

What is the difference between the MVD-335 PRO and the MVD-335?

The PRO starts at 10 V instead of 200 V, reaches 500 kV instead of 220 kV and phases up to 200 m apart instead of 30 m. The MVD-335 keeps more records (9999 vs 200), so it suits distribution networks up to 220 kV where long distances are not needed.

Can I use it to check motor rotation?

It shows phase sequence on the network. For quick rotation checks on low-voltage 3-phase motors and sockets, a dedicated LV phase rotation tester is simpler.

Additional information
Brand

Marmonix

Measurement functions

Frequency

,

High-voltage phasing

,

Phase angle

,

Phase sequence

Display

Colour display

Connectivity & outputs

Wireless (RF)

Power source

9 V battery

,

AA batteries

Features

Data logging

,

Voice prompts

Applications

Power utilities

Voltage measurement range

10 V-500 kV

Downloads

Downloads

Marmonix MVD-335 PRO datasheet PDF

 

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Marmonix MVD-335 PRO Wireless High-Voltage Phase Detector, 10 V–500 kV”

Your email address will not be published. Required fields are marked *