Marmonix MIT 900 (MIT-900 / MIT900) Infrared Thermometer, −50 to 950 °C, 12:1

SKU: MIT 900 Category:

Marmonix MIT 900 high-temperature infrared thermometer for furnaces, kilns and hot exhausts: −50 to 950 °C, 12:1 optic, laser aiming, emissivity 0.10–1.00, MAX/MIN/AVG/DIF, alarms and 30 memories. Datasheet-backed specs and UAE/GCC supply.

WhatsApp
Email
Telegram
Description

When a handheld IR gun has to read a furnace shell, kiln wall, ladle or exhaust that can climb past 750 °C, most 400–650 °C models run out of range. The Marmonix MIT 900 (also listed as MIT-900 / MIT900) is the high-heat pistol in our line: −50 to 950 °C, 12:1 optic, laser aiming and adjustable emissivity in a 220 g body. It belongs in the Marmonix infrared and contact thermometer range.

Use it for hot industrial surfaces you should not touch. For heat patterns across a whole panel or machine, step up to a thermal camera — start with our thermal imaging camera buyer’s guide or the thermal imaging industrial inspection guide.

Why plant teams pick the MIT 900

  • 950 °C ceiling for furnace casings, kilns, refractory, molten-metal areas and hot exhausts
  • 12:1 distance-to-spot with laser aiming so you can stand back from the heat
  • ±1.5 °C or ±1.5% accuracy from 0 to 950 °C (whichever is greater); ±3 °C below 0 °C
  • Adjustable emissivity 0.10–1.00 (0.95 preset) for oxidised steel, paint, refractory and rubber
  • 500 ms response (95%) on an 8–14 µm thermopile detector
  • MAX / MIN / AVG / DIF, high and low alarms, data hold, °C/°F and a backlit LCD
  • 30 memory slots for a round of inspection points
  • About 22 h on a 9 V cell without the laser (12 h with laser); 2-year warranty

Where the MIT 900 is used

  • Metals, glass and cement: furnace and kiln shells, ladles, die temperatures, refractory hot spots
  • Oil, gas and petrochemical: insulated flanges, steam lines, heat-exchanger bodies and flare-related surfaces during rounds
  • Power and electrical: switchgear terminals, cable lugs and transformer bodies from a safe distance — pair with a thermal camera for a full panel scan
  • HVAC and district cooling: compressor discharge pipes and high-temperature plant rooms
  • Automotive, marine and generators: exhaust manifolds, turbos, catalytic converters and engine-room equipment
  • Food and catering plant: oven decks, griddles and fryer surfaces where contact probes are impractical

MIT 900 specifications

Values are taken from the official Marmonix MIT 900 datasheet (part number 7603131).

Parameter MIT 900
Part number / GTIN 7603131 / 6298043998192
Temperature range −50 to 950 °C (−58 to 1742 °F)
Accuracy (0 to 950 °C) ±1.5 °C (±2.7 °F) or ±1.5% of reading, whichever is greater
Accuracy (−50 to 0 °C) ±3 °C (±5 °F)
Resolution 0.1 °C or 0.1 °F
Repeatability 1% of reading or 1 °C
Response time 500 ms (95% response)
Spectral response 8–14 µm
Emissivity 0.10–1.00 adjustable (0.95 preset)
Distance-to-spot ratio 12:1
Functions MAX / MIN / AVG / DIF, high & low alarms, data hold, °C/°F, laser aiming, backlight, 30 memories
Operating temperature 0 to 40 °C (32 to 104 °F)
Operating humidity 10–95% RH non-condensing, up to 30 °C
Storage temperature −20 to 60 °C (−4 to 140 °F)
Power 9 V alkaline or NiCd battery
Typical battery life (alkaline) About 22 h without laser; 12 h with laser
Dimensions / weight 175 × 100 × 49 mm / 220 g
Package contents MIT 900 main unit, 9 V battery, protective case, user manual, certificate of conformity, warranty card
Warranty 2 years (excludes consumables such as batteries)

How to take a reliable IR reading

  1. Fit the 9 V battery, power on and select °C or °F.
  2. Set emissivity for the surface: leave 0.95 for most painted, oxidised or organic materials; lower it for bright metal, or apply matt tape/paint and measure that patch.
  3. Mind the spot size (distance ÷ 12). Make sure the target fills — preferably exceeds — the spot.
  4. Aim with the laser, pull the trigger, and wait for the 500 ms response to settle. Sweep while watching MAX to find the hottest point.
  5. Set HI/LO alarms for pass/fail rounds and store key points in the 30 memories.
  6. Remember: IR reads surfaces only. For air, liquids or core temperature use the {MST}.

Safety: never point the laser at eyes or reflective surfaces that could redirect it. Do not measure through glass or heavy steam/dust. Avoid strong electromagnetic fields from welders or induction heaters, and allow about 30 minutes for the instrument to stabilise after a large ambient-temperature change.

MIT 900 vs other IR thermometers sold in the UAE / GCC

Figures below are from each maker’s published specifications. The MIT 900’s stand-out is the 950 °C range; ruggedness-focused meters such as Fluke 62 MAX+ trade a lower max temperature for IP54 and drop ratings.

Model Range D:S Accuracy (published) Emissivity Response Notes
Marmonix MIT 900 −50 to 950 °C 12:1 ±1.5 °C or ±1.5% (0–950 °C) 0.10–1.00 500 ms 30 memories, HI/LO alarms
Fluke 62 MAX+ −30 to 650 °C 12:1 ±1.0 °C or ±1.0% (typical band) 0.10–1.00 <500 ms IP54, 3 m drop; dual laser
Hioki FT3700-20 −60 to 550 °C 12:1 ±2 °C (0–100 °C); ±2% (100–500 °C) 0.10–1.00 1 s (90%) Two-point laser marker
Hioki FT3701-20 −60 to 760 °C 30:1 Similar Hioki accuracy bands 0.10–1.00 1 s (90%) Longer-focus precise field
Testo 830-T2 −30 to 400 °C 12:1 ±1.5 °C or ±1.5% (typical) 0.10–1.00 ~0.5 s 2-point laser; lower max temp

Which Marmonix MIT model should you buy?

Model Range Best for
MIT 900 (this page) −50 to 950 °C Furnaces, kilns, metals, exhausts above 750 °C
MIT-700 −50 to 750 °C Heavy maintenance that stays below 750 °C
MIT 550e −50 to 550 °C General industrial and electrical surface checks
MIT-320 −50 to 400 °C HVAC and everyday surface checks (0.95 preset)

Choose the MIT 900 whenever any target can exceed 750 °C. If your work stays cooler, the MIT-700 or MIT 550e covers it at a lower cost. Need an area heat map instead of a spot? See the thermal camera buyer’s guide.

Buying the MIT 900 in the UAE and GCC

Marmonix supplies the MIT 900 directly with the official datasheet, user manual, certificate of conformity and a 2-year warranty. Local support covers Dubai, Abu Dhabi and the wider GCC. Ask us for a quote, multi-unit pricing for site teams, or help matching emissivity practice to your surfaces. Datasheet and manual PDFs are in the Downloads tab.

MIT 900 frequently asked questions

What is the maximum temperature of the Marmonix MIT 900?

It measures surface temperature from −50 to 950 °C (−58 to 1742 °F). Between 0 and 950 °C accuracy is ±1.5 °C or ±1.5% of reading, whichever is greater; below 0 °C it is ±3 °C.

How does the 12:1 distance-to-spot ratio work?

The measurement spot diameter is roughly distance ÷ 12. At 60 cm the spot is about 5 cm across; at 1.2 m it is about 10 cm. Keep the target larger than the spot — ideally at least twice the spot diameter for critical readings.

Why does polished metal read too low?

Bright metals have low emissivity and reflect their surroundings. Lower the emissivity setting from the 0.95 preset, or cover a patch with matt tape or paint, let it reach the surface temperature, then measure that patch.

How is the MIT 900 different from the MIT-700 or MIT 550e?

Range is the main difference. The MIT 900 reaches 950 °C; the MIT-700 stops at 750 °C and the MIT 550e at 550 °C. All three offer a 12:1 optic and adjustable emissivity. Pick the MIT 900 when any target can exceed 750 °C.

Can the MIT 900 measure air or liquid temperature?

No. Like other infrared thermometers it reads surface temperature only. It cannot see through glass, steam or dust. For air, liquids or core temperature use a contact probe such as the {MST}.

What is in the box and how long is the warranty?

The package includes the MIT 900, a 9 V battery, protective storage case, user manual, certificate of conformity and warranty card. Marmonix covers the instrument with a 2-year warranty excluding consumables such as batteries. Part number 7603131, GTIN 6298043998192.

How does it compare with Fluke 62 MAX+ or Hioki FT3700 in the UAE?

Fluke 62 MAX+ is tougher (IP54, 3 m drop) but tops out at 650 °C. Hioki FT3700-20 offers a clear two-point laser and long battery life but stops at 550 °C (FT3701-20 reaches 760 °C with a 30:1 optic). The MIT 900’s advantage is the 950 °C ceiling for furnace, kiln and molten-metal work at a mid-range price.

Where can I buy the MIT 900 in the UAE and GCC?

Order from Marmonix with local support across the UAE and supply across the GCC. The datasheet and user manual are in the Downloads tab; contact us for quotes and multi-unit orders.

Additional information
Brand

Marmonix

Measurement functions

Infrared temperature

Display

Backlit LCD

Power source

9 V battery

Features

Adjustable emissivity

,

Alarm

,

Backlight

,

Data hold

,

Data logging

,

Laser pointer

,

Max/Min

Applications

Automotive

,

Electrical

,

HVAC

,

Industrial maintenance

Temperature measuring range

-50~950 °C

Distance-to-spot ratio (D:S)

12:1

Mounting / format

Handheld

Downloads

Downloads

Download Marmonix MIT 900 infrared thermometer datasheet (PDF)

Download Marmonix MIT 900 infrared thermometer user manual (PDF)

 

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Marmonix MIT 900 (MIT-900 / MIT900) Infrared Thermometer, −50 to 950 °C, 12:1”

Your email address will not be published. Required fields are marked *