Site icon Marmonix Test and Measuring Tools

Wall Mounted Ultrasonic Flowmeter MFU-6300

MFU-6300-MARMONIX

MFU-6300-MARMONIX Portable Ultrasonic Flow meter

Wall Mounted Ultrasonic Flowmeter MFU-6300

Wall Mounted Ultrasonic Flowmeter MFU-6300 widely used to measure different kinds of liquid.
Transmitter and transducer install separately. Transmitter can install at indoor, Instrument cabinet, Dashboard.
Transducer install on the pipes. Transmitter and Transducer connect by special cable.
It can realize to measure flow. Connect with temperature sensor, it can measure heat flow.
Widely used in Running water, Heating, Water conservation, Metallurgy, Chemical industry, Machinery, Energy etc.
Used for production monitoring, water balance testing, thermal equilibrium network commissioning, energy monitoring. It is most important flow measure instrument during manufacturing process.

Wall Mounted Ultrasonic Flowmeter MFU-6300 Features

 

Wall Mounted Ultrasonic Flowmeter MFU-6300 Specifications:

Type Performance, Specification
Principle Ultrasonic transit-time principle, Four-byte IEEE754 floating-point arithmetic
Accuracy Better than ±1%
Display LCD display with Chinese, English Display
One 4-20mA Current output,Impedance0-1K,Accuracy 0.1%
Output One OCT Pulse output(Width 6-1000ms,Default200ms)
Transmitter One Relays output
Input Three4-20mACurrentinput,accuracy0.1%,cancollecttemperature,pressure,levelsignalsetc
Can connect with three-wire PT100 Platinum resistance to measure heat flow
Data Interface Isolated RS485 interface, can upgrade flowmeter through PC, support mudbug
Cable Normal below 50m;Select RS485 Communication, Transmission distance can over thousand meters.
material Steel, Stainless steel, Cast iron, copper, PVC, aluminum, FRP etc.(liner allowed)
Pipe condition Diameter 15~6000mm
Installation Upstream 10D,downstream 5D,30D away from the pump outlet(D for diameter)
Medium Fluid Water, sea water, acid liquid, beer, alcohol, oil and any other liquid that can spread sonic
Temperature -30~160 degree C
Turbidity 10000ppm and with little bubbles
Velocity 0~±10m s
Operating Environment Temperature Transmitter:-20~60 degree C; Transducer:-30~160 degree C
Humidity Transmitter:85%RH;transmitter protection grade:IP68;Water Depth<2m
Power Supply DC8-36V or AC85-264V
Consumption 1.5W

 

Exit mobile version