Site icon Marmonix Test and Measuring Tools

Ultrasonic Level Sensor MLS-2204

Ultrasonic Level Sensor MLS-2204

Ultrasonic Level Sensor MLS-2204

Ultrasonic Level Sensor MLS-2204

The sensor of the meter pulses in the direction of the product surface. There, they are reflected back and received by the sensor. The Ultrasonic Level Transmitter Marmonix MLS-2204 measures the time t between pulse transmission and reception. The meter uses the time t (and the velocity of sound) to calculate the distance D between the sensor membrane and the product surface:
D = c •t/2. As the device knows the empty distance H from a user entry, it can calculate the level as follows: L= H – D.
The ultrasonic velocity in gas is influenced by the gas temperature, so the level meter need to detect the gas temperature at work. So the material level meter need to detect the gas temperature at work, compensation for sound velocity.
Blanking distance: Span F may not extend into the blanking distance B. Level echo from the blanking distance cannot be evaluated due to the transient characteristics of the sensor.

Ultrasonic Level Sensor MLS-2204 Features

 

Ultrasonic Level Sensor MLS-2204 Specifications:

Power supply DC24V (±10%) 30mA
Display 4 digit LCD
Display resolution 0.03% of the actual range
Output current 4-20mA
Output load 0-500Ω
Temperature range -40 ℃~75℃
Pressure range ±0.1MPa (press definitely)
Temperature compensation full range of automatic compensation
Cable diameter Φ 6 ~ Φ12 mm
Single wire diameter Φ0.5 ~ Φ1.78 mm
Measuring Cycle 1.5 seconds
8º(3db) for range Plane Type Sensor (4m 6m 8m 12m 20m 30m)
5º(3db) for range Horn Type Sensor (20m,30m)
Electronic unit shell material die-casting aluminum with plastic-sprayed surface
The sensor material ABS/PVC/PTFE
Protect grade IP67

 

Exit mobile version